<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Generador Estático de Reactiva &#8211; Improtek Chile</title>
	<atom:link href="https://www.improtek.cl/categoria-producto/compensacion-de-energia-reactiva-y-filtrado-de-armonicos/generador-estatico-de-reactiva/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.improtek.cl</link>
	<description>Productos y Servicios Industriales</description>
	<lastBuildDate>Thu, 02 Oct 2025 16:48:42 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.4.8</generator>

<image>
	<url>https://www.improtek.cl/wp-content/uploads/2022/03/cropped-icono-logoimprotek-32x32.png</url>
	<title>Generador Estático de Reactiva &#8211; Improtek Chile</title>
	<link>https://www.improtek.cl</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Circutor SVGm-3WF-30M-480 &#124; Generador Estático de Reactiva Multinivel de 30 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-3wf-30m-480/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 16:48:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10859</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-3WF-30M-480</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 3 hilos, 230...480 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 17,4 &#124; kvar (400 V): 30 &#124; <i class="ico-ballot-check"></i>kvar (440 V): 30 &#124; <i class="ico-ballot-check"></i>kvar (480 V): 30</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 44</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 480</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 30 kvar Circutor SVGm-3WF-30M-480 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-30M-480:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo</li>
<li>Monitorización del funcionamiento vía Web</li>
<li>Protección contra circuitos en su interior</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-30M-480:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="259" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>650 W (Consumo máximo)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 480 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>430 x 530 x 178 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>58 dBA, A 1m de la pared de montaje. Certificado ISO 11201:2010 V2</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>21</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP20</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>44 A (RMS)</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5 / 5A &#8230; 5000 / 5A</td>
</tr>
<tr>
<td><strong>Comunicación red</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m sin limitar prestaciones)</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (Kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo:</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 µs</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td><strong>Comunicación serie</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus / RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-3WF-30M-480 | Generador Estático de Reactiva Multinivel de 30 kvar 1" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-3WF-30M-480</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-3WF-30M-480 | Generador Estático de Reactiva Multinivel de 30 kvar 2" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-3WF-60M-480 &#124; Generador Estático de Reactiva Multinivel de 60 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-3wf-60m-480/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 16:45:26 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10858</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-3WF-60M-480</h2>
<div class="desc_producto">
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 3 hilos, 230...480 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 34,5 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 60 &#124; <i class="ico-ballot-check"></i>kvar (440 V): 60 &#124; <i class="ico-ballot-check"></i>kvar (480 V): 60</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 88</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 480</li>
</ul>
</div>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 60 kvar Circutor SVGm-3WF-60M-480 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-60M-480:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo</li>
<li>Monitorización del funcionamiento vía Web</li>
<li>Protección contra circuitos en su interior</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-60M-480:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="259" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1300 W (Consumo máximo)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 480 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>430 x 530 x 348 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>60 dBA, A 1m de la pared de montaje. Certificado ISO 11201:2010 V2</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>39</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP20</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>88 A (RMS)</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5 / 5A &#8230; 5000 / 5A</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m sin limitar prestaciones)</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (Kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 µs</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-3WF-60M-480 | Generador Estático de Reactiva Multinivel de 60 kvar 3" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-3WF-60M-480</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-3WF-60M-480 | Generador Estático de Reactiva Multinivel de 60 kvar 4" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-3WF-100M-480 &#124; Generador Estático de Reactiva Multinivel de 100 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-3wf-100m-480/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 16:37:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10857</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-3WF-100M-480</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 3 hilos, 230...480 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 57,5 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 100 &#124; <i class="ico-ballot-check"></i>kvar (440 V): 100 &#124; <i class="ico-ballot-check"></i>kvar (480 V): 100</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 145</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 480</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 100 kvar Circutor SVGm-3WF-100M-480 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-100M-480:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo</li>
<li>Monitorización del funcionamiento vía Web</li>
<li>Protección contra circuitos en su interior</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-100M-480:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="259" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>2070 W (Consumo máximo)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 480 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>439 x 745 x 288 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>&lt; 60 dBA</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>56</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP20</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>145 A (RMS)</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5 / 5A &#8230; 5000 / 5A</td>
</tr>
<tr>
<td><strong>Comunicación red</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m sin limitar prestaciones)</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (Kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 µs</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td><strong>Comunicación serie</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus / RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-3WF-100M-480 | Generador Estático de Reactiva Multinivel de 100 kvar 5" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-3WF-100M-480</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-3WF-100M-480 | Generador Estático de Reactiva Multinivel de 100 kvar 6" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-3WF-100C-480 &#124; Generador Estático de Reactiva Multinivel de 100 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-3wf-100c-480/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 16:33:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10856</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-3WF-100C-480</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 3 hilos, 230...480 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 57,5 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 100 &#124; <i class="ico-ballot-check"></i>kvar (440 V): 100 &#124; <i class="ico-ballot-check"></i>kvar (480 V): 100</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 145</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 480</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 100 kvar Circutor SVGm-3WF-100C-480 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-100C-480:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo</li>
<li>Monitorización del funcionamiento vía Web</li>
<li>Protección contra circuitos en su interior</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-100C-480:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="274" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Categoría de la instalación</td>
<td>4 kV, CAT III Clase 1</td>
</tr>
<tr>
<td>Consumo</td>
<td>2070 W (max.)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 480 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>608 x 1890 x 812 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>&lt; 60 dBA</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>190</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP 21 / IK10 (IP 41 bajo demanda)</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Instalación, lugar, posición.</td>
<td>Instalación en entornos tipo A</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente de cortocircuito condicional (Icc)</td>
<td>40 kA</td>
</tr>
<tr>
<td>Corriente de cresta Ipk</td>
<td>84 kA pico</td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>145 A (RMS)</td>
</tr>
<tr>
<td>Factor de Simultaneidad (RDF)</td>
<td>1</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5/5A &#8230; 5000/5A</td>
</tr>
<tr>
<td><strong>Comunicación red</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m without performance degradation)</td>
</tr>
<tr>
<td>Seguridad eléctrica, Grado de contaminación</td>
<td>Categoría 2</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (Kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 $\mu$s</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td><strong>Comunicación serie</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus/RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-3WF-100C-480 | Generador Estático de Reactiva Multinivel de 100 kvar 7" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-3WF-100C-480</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-3WF-100C-480 | Generador Estático de Reactiva Multinivel de 100 kvar 8" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-3WF-200C-480 &#124; Generador Estático de Reactiva Multinivel de 200 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-3wf-200c-480/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 16:27:58 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10855</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-3WF-200C-480</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 3 hilos, 230...480 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 115 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 200 &#124; <i class="ico-ballot-check"></i>kvar (440 V): 200 &#124; <i class="ico-ballot-check"></i>kvar (480 V): 200</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 290</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 480</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 200 kvar Circutor SVGm-3WF-200C-480 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-200C-480:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo</li>
<li>Monitorización del funcionamiento vía Web</li>
<li>Protección contra circuitos en su interior</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-3WF-200C-480:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="274" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Categoría de la instalación</td>
<td>4 kV, CAT III Clase 1</td>
</tr>
<tr>
<td>Consumo</td>
<td>4140 W (max.)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 480 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>608 x 1890 x 812 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>&lt; 63 dBA</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>245</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP 21 / IK10 (IP 41 bajo demanda)</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Instalación, lugar, posición.</td>
<td>Instalación en entornos tipo A</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente de cortocircuito condicional (Icc)</td>
<td>40 kA</td>
</tr>
<tr>
<td>Corriente de cresta Ipk</td>
<td>84 kA pico</td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>290 A (RMS)</td>
</tr>
<tr>
<td>Factor de Simultaneidad (RDF)</td>
<td>1</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5/5A &#8230; 5000/5A</td>
</tr>
<tr>
<td><strong>Comunicación red</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m without performance degradation)</td>
</tr>
<tr>
<td>Seguridad eléctrica, Grado de contaminación</td>
<td>Categoría 2</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (Kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 $\mu$s</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td><strong>Comunicación serie</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus/RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-3WF-200C-480 | Generador Estático de Reactiva Multinivel de 200 kvar 9" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-3WF-200C-480</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-3WF-200C-480 | Generador Estático de Reactiva Multinivel de 200 kvar 10" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-4WF-020M-400 &#124; Generador Estático de Reactiva Multinivel de 20,7 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-4wf-020m-400/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 16:11:30 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10854</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-4WF-020M-400</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 4 hilos, 230...400 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 12 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 20,7</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 30</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 400</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 20,7 kvar Circutor SVGm-4WF-020M-400</span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-020M-400:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario.</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar.</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas.</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo.</li>
<li>Monitorización del funcionamiento vía Web.</li>
<li>Protección contra circuitos en su interior.</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-020M-400:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="259" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>650 W (Consumo máximo)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 400 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>430 x 530 x 178 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>58 dBA, A 1m de la pared de montaje, Certificado ISO 11201:2010 V2</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>21</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP20</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>30 A (RMS)</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5/5A &#8230; 5000/5A</td>
</tr>
<tr>
<td><strong>Comunicación red</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m sin limitar prestaciones)</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (Kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 $\mu$s</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td><strong>Comunicación serie</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus/RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<div></div>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-4WF-020M-400 | Generador Estático de Reactiva Multinivel de 20,7 kvar 11" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-4WF-020M-400</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-4WF-020M-400 | Generador Estático de Reactiva Multinivel de 20,7 kvar 12" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-4WF-050M-400 &#124; Generador Estático de Reactiva Multinivel de 51,7 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-4wf-050m-400/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 16:03:16 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10853</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-4WF-050M-400</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 4 hilos, 230...400 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 30 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 51,7</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 75</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 400</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 51,7 kvar Circutor SVGm-4WF-050M-400 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-050M-400:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario.</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar.</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas.</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo.</li>
<li>Monitorización del funcionamiento vía Web.</li>
<li>Protección contra circuitos en su interior.</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-050M-400:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="227" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td>Alimentación en alterna</td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1550 W (Consumo máximo)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 400 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td>Características mecánicas</td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>439 x 745 x 288 (mm)</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>56</td>
</tr>
<tr>
<td>Características ambientales</td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP20</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td>Características eléctricas</td>
<td></td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>72 A (RMS)</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td>Circuito de medida de corriente</td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5/5A &#8230; 5000/5A</td>
</tr>
<tr>
<td>Comunicación red</td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td>Normas</td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m sin limitar prestaciones)</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td>Comunicación serie</td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus/RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-4WF-050M-400 | Generador Estático de Reactiva Multinivel de 51,7 kvar 13" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-4WF-050M-400</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-4WF-050M-400 | Generador Estático de Reactiva Multinivel de 51,7 kvar 14" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-4WF-069M-400 &#124; Generador Estático de Reactiva Multinivel de 69 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-4wf-069m-400/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 15:57:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10852</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-4WF-069M-400</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 4 hilos, 230...400 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 40 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 69</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 100</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 400</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 69 kvar Circutor SVGm-4WF-069M-400 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-069M-400:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo</li>
<li>Monitorización del funcionamiento vía Web</li>
<li>Protección contra circuitos en su interior</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-069M-400:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="259" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>2070 W (Consumo máximo)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 400 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>439 x 745 x 288 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>&lt; 60 dBA</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>56</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP20</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>100 A (RMS)</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1,5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5/5A &#8230; 5000/5A</td>
</tr>
<tr>
<td><strong>Comunicación red</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m sin limitar prestaciones)</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (Kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 $\mu$s</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus/RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-4WF-069M-400 | Generador Estático de Reactiva Multinivel de 69 kvar 15" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-4WF-069M-400</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-4WF-069M-400 | Generador Estático de Reactiva Multinivel de 69 kvar 16" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-4WF-207C-400 &#124; Generador Estático de Reactiva Multinivel de 207 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-4wf-207c-400/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 15:52:46 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10851</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-4WF-207C-400</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 4 hilos, 230...400 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 119,1 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 207</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 300</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 400</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 207 kvar Circutor SVGm-4WF-207C-400 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-207C-400:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario.</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar.</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas.</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo.</li>
<li>Monitorización del funcionamiento vía Web.</li>
<li>Protección contra circuitos en su interior.</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-207C-400:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="274" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td>Alimentación en alterna</td>
<td></td>
</tr>
<tr>
<td>Categoría de la instalación</td>
<td>4 kV, CAT III Clase 1</td>
</tr>
<tr>
<td>Consumo</td>
<td>6210 W (max.)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 400 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td>Características mecánicas</td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>608 x 1890 x 812 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>&lt; 65 dBA</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>300</td>
</tr>
<tr>
<td>Características ambientales</td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP 21 / IK10 (IP 41 bajo demanda)</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Instalación, lugar, posición</td>
<td>Instalación en entornos tipo A</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td>Características eléctricas</td>
<td></td>
</tr>
<tr>
<td>Corriente de cortocircuito condicional (Icc)</td>
<td>40 kA</td>
</tr>
<tr>
<td>Corriente de cresta Ipk</td>
<td>84 kA pico</td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>300 A (RMS)</td>
</tr>
<tr>
<td>Factor de Simultaneidad (RDF)</td>
<td>1</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td>Circuito de medida de corriente</td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1.5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador x / 5A, 5000 / 5A</td>
</tr>
<tr>
<td>Comunicación red</td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td>Normas</td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m without performance degradation)</td>
</tr>
<tr>
<td>Seguridad eléctrica, Grado de contaminación</td>
<td>Categoría 2</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td>Prestaciones</td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 µs</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td>Comunicación serie</td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus/RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<div></div>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-4WF-207C-400 | Generador Estático de Reactiva Multinivel de 207 kvar 17" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-4WF-207C-400</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-4WF-207C-400 | Generador Estático de Reactiva Multinivel de 207 kvar 18" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Circutor SVGm-4WF-276C-400 &#124; Generador Estático de Reactiva Multinivel de 276 kvar</title>
		<link>https://www.improtek.cl/producto/circutor-svgm-4wf-276c-400/</link>
		
		<dc:creator><![CDATA[Carolina_C_A]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 15:46:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.improtek.cl/?post_type=product&#038;p=10850</guid>

					<description><![CDATA[<h2>Generador Estático de Reactiva Circutor SVGm-4WF-276C-400</h2>
<ul class="caracteriscas-producto">
 	<li>Filtro EMI: 1</li>
 	<li><i class="ico-ballot-check"></i>Sistema: 4 hilos, 230...400 V</li>
 	<li><i class="ico-ballot-check"></i>kvar (230 V): 159 &#124; <i class="ico-ballot-check"></i>kvar (400 V): 276</li>
 	<li><i class="ico-ballot-check"></i>Corriente de fase: 400</li>
 	<li><i class="ico-ballot-check"></i>Tensión uso (V): 400</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #01577a;">Generador Estático de Reactiva Multinivel de 276 kvar Circutor SVGm-4WF-276C-400 </span></h2>
<p>Los generadores estáticos de reactiva tipo armario <strong>SVGm </strong>constituyen la solución más precisa para la compensación de potencia reactiva, tanto en sistemas trifásicos desequilibrados como en instalaciones con potencia reactiva ya sea inductiva como capacitiva. Puede ser utilizado tanto en instalaciones trifásicas industriales como comerciales o de servicios, y no se ve afectado por los armónicos de la instalación. Equipo con mayor seguridad y con un mantenimiento muy reducido. En esta serie, el montaje de los racks se realiza en armarios estándares del mercado, diseñados para facilitar su instalación.</p>
<h3><span style="color: #01577a; font-size: 110%;">Características Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-276C-400:</span></h3>
<ul>
<li>Compensación de potencia reactiva (inductiva/capacitiva) de 30 a 100 kvar (3W) y 20 a 69 kvar (4W) por armario</li>
<li>Dimensiones reducidas del módulo de 100 kvar (3W) y 69 kvar (4W) tipo rack para instalarlo fácilmente en armarios estándar</li>
<li>Multirango de tensión y frecuencia (50/60 Hz)</li>
<li>Inmunidad a las corrientes armónicas</li>
<li>Rango de cos φ de 0,7 inductivo…1…0,7 capacitivo</li>
<li>Monitorización del funcionamiento vía Web</li>
<li>Protección contra circuitos en su interior</li>
</ul>
<p>Si se requieren mayores capacidades de compensación de reactiva, pueden conectarse en paralelo hasta 100 equipos.</p>
<p><strong><span style="font-size: 110%; color: #202121;">Aplicaciones:</span></strong></p>
<p>Solución ideal para cargas individuales o instalaciones con gran cantidad de cargas monofásicas y trifásicas ya sean inductivas o capacitivas. También, en instalaciones donde la carga fluctúe en periodos cortos de tiempo, cargas típicas serían puentes grúa, equipos de soldadura, ascensores, accionamiento para la perforación / trituración, centros de datos.</p>
<h3><span style="color: #01577a; font-size: 110%;">Especificaciones Circutor </span><span style="color: #01577a; font-size: 110%;">SVGm-4WF-276C-400:</span></h3>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="274" />
<col width="666" /></colgroup>
<tbody>
<tr>
<td><strong>Alimentación en alterna</strong></td>
<td></td>
</tr>
<tr>
<td>Categoría de la instalación</td>
<td>4 kV, CAT III Clase 1</td>
</tr>
<tr>
<td>Consumo</td>
<td>6280 W (max.)</td>
</tr>
<tr>
<td>Frecuencia</td>
<td>50 / 60 Hz ± 5 %</td>
</tr>
<tr>
<td>Tensión nominal</td>
<td>208 &#8230; 400 V~ F-F (± 10 %)</td>
</tr>
<tr>
<td><strong>Características mecánicas</strong></td>
<td></td>
</tr>
<tr>
<td>Tamaño (mm) ancho x alto x fondo</td>
<td>608 x 1890 x 812 (mm)</td>
</tr>
<tr>
<td>Ruido</td>
<td>&lt; 66 dBA</td>
</tr>
<tr>
<td>Peso Neto (kg)</td>
<td>355</td>
</tr>
<tr>
<td><strong>Características ambientales</strong></td>
<td></td>
</tr>
<tr>
<td>Grado de protección</td>
<td>IP 21 / IK10 (IP 41 bajo demanda)</td>
</tr>
<tr>
<td>Humedad relativa (sin condensación)</td>
<td>0 &#8230; 95 %</td>
</tr>
<tr>
<td>Instalación, lugar, posición</td>
<td>Instalación en entornos tipo A</td>
</tr>
<tr>
<td>Temperatura de almacenamiento</td>
<td>-20 &#8230; +50 °C</td>
</tr>
<tr>
<td>Temperatura de trabajo</td>
<td>-10 &#8230; +45 °C</td>
</tr>
<tr>
<td><strong>Características eléctricas</strong></td>
<td></td>
</tr>
<tr>
<td>Corriente de cortocircuito condicional (Icc)</td>
<td>40 kA</td>
</tr>
<tr>
<td>Corriente de cresta Ipk</td>
<td>84 kA pico</td>
</tr>
<tr>
<td>Corriente máxima (fase)</td>
<td>400 A (RMS)</td>
</tr>
<tr>
<td>Factor de Simultaneidad (RDF)</td>
<td>1</td>
</tr>
<tr>
<td>Sistema de tierras</td>
<td>TN, TT</td>
</tr>
<tr>
<td><strong>Circuito de medida de corriente</strong></td>
<td></td>
</tr>
<tr>
<td>Consumo</td>
<td>1.5 VA por transformador</td>
</tr>
<tr>
<td>Relación de transformación</td>
<td>Transformador: 5/5A &#8230; 5000/5A</td>
</tr>
<tr>
<td><strong>Comunicación red</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>TCP/IP, Modbus TCP</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>Ethernet</td>
</tr>
<tr>
<td><strong>Normas</strong></td>
<td></td>
</tr>
<tr>
<td>Seguridad eléctrica, Altitud máx. (m)</td>
<td>3000 (2000 m without performance degradation)</td>
</tr>
<tr>
<td>Seguridad eléctrica, Grado de contaminación</td>
<td>Categoría 2</td>
</tr>
<tr>
<td>Normas</td>
<td>IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (indoor conditioned)</td>
</tr>
<tr>
<td><strong>Prestaciones</strong></td>
<td></td>
</tr>
<tr>
<td>Compensación de potencia reactiva (kvar)</td>
<td>Seleccionable: 0,7 inductivo &#8230; 1 &#8230; 0,7 capacitivo</td>
</tr>
<tr>
<td>Filtrado / tiempo de respuesta</td>
<td>&lt; 100 µs</td>
</tr>
<tr>
<td>Montaje en paralelo</td>
<td>Hasta 100 dispositivos de diferente calibre. Conexión de los transformadores solo en unidad Master.</td>
</tr>
<tr>
<td><strong>Comunicación serie</strong></td>
<td></td>
</tr>
<tr>
<td>Protocolo</td>
<td>Modbus/RTU</td>
</tr>
<tr>
<td>Tecnología / Tipo</td>
<td>RS-485</td>
</tr>
</tbody>
</table>
<div></div>
<figure id="attachment_10800" aria-describedby="caption-attachment-10800" style="width: 600px" class="wp-caption alignnone"><img loading="lazy" decoding="async" class="wp-image-10800" src="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp" alt="afwm 3wf 075m 480 conexion" width="600" height="600" title="Circutor SVGm-4WF-276C-400 | Generador Estático de Reactiva Multinivel de 276 kvar 19" srcset="https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-300x300.webp 300w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-150x150.webp 150w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-768x768.webp 768w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-600x600.webp 600w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion-100x100.webp 100w, https://www.improtek.cl/wp-content/uploads/2025/10/afwm-3wf-075m-480-conexion.webp 800w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-10800" class="wp-caption-text">Conexión</figcaption></figure>
<p>&nbsp;</p>
<p><a href="https://docs.circutor.com/docs/M248B01-01.pdf" target="_blank" rel="noopener"><strong><span style="color: #0000ff;">MANUAL SVGm-4WF-276C-400</span></strong></a></p>
<p><a href="https://www.improtek.cl/?s=circutor&amp;post_type=product"><img loading="lazy" decoding="async" class="alignnone wp-image-284" src="https://www.improtek-latam.com/wp-content/uploads/2021/12/logo-circutor.png" alt="logo circutor" width="223" height="168" title="Circutor SVGm-4WF-276C-400 | Generador Estático de Reactiva Multinivel de 276 kvar 20" srcset="https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor.png 798w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-600x451.png 600w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-300x226.png 300w, https://www.improtek.cl/wp-content/uploads/2021/12/logo-circutor-768x577.png 768w" sizes="(max-width: 223px) 100vw, 223px" /></a></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
